FACTORY & LABORATORY
Materials, processing & supply
Explore the production environment behind the material supply. Contact us to confirm current material specifications and availability.
Discuss your material requirements
From the site to the sample, see the context behind the material.
Company introduction
About VORAFIB
This website is dedicated to our mineral fiber and related materials business, with a separate catalogue and enquiry presentation.
Browse materials, review available technical references, and contact us to discuss your requirements.
MATERIALS / PROCESSING / APPLICATIONS
From material to application.
Watch the 59-second introduction to materials, processing, laboratory review and warehousing.
INSIDE THE LABORATORY
Equipment. Methods. Context.
A visual introduction to the equipment and measurement references. Open the notes for the principle, calculation and conditions behind each test.

Method-reference photograph
Density testing equipment
A closer look at the equipment used to measure how a fiber sample packs.
Read measurement notes
Method-reference photograph
Fiber measurement references
Density, length and diameter methods, with their measurement basis explained.
Read measurement notes
Method-reference photograph
Moisture & ignition loss
Two heating procedures, with different conditions and different meanings.
Read measurement notes
Method-reference photograph
Non-fibrous shot content
Wet separation and sieving, read together with the specified sieve opening.
Read measurement notesThese supplied method-reference photographs retain their original equipment and manufacturer markings. They provide method context, rather than evidence of VORAFIB laboratory ownership or accreditation. Current grade datasheets and agreed methods remain the basis for specification enquiries.
PACKAGING & SAMPLES
Keep the sample
connected to the data.
Packaging and identification are part of the material enquiry. Confirm the grade designation, sample reference, packing format and required quantity.
For a trial sample or a later delivery, ask for the current datasheet and the agreed batch information. Record any conditioning or preparation changes when comparing results.
The supplied packaging references retain their original manufacturer markings. Confirm the packing format and identification for your selected material.
Discuss a sample or packaging
Packaging reference photograph
Packaging materials
Confirm packing format and quantity for the selected material.

Packaging reference photograph
Sample identification
Keep the sample reference connected to its grade and current datasheet.
FROM TEST RESULTS TO A SHORTLIST
Compare the limits that matter to your process.
Choose a product range and, if you have agreed limits, enter them below. This compares published catalogue limits; it does not predict performance or rank the grades.
3 catalogue grades listed.
Catalogue grades in this range
| Grade | Moisture / drying loss max. | Ignition loss max. | Shot max. | Tap density | Average length | Average diameter | Next step |
|---|---|---|---|---|---|---|---|
| MF-DBP-A | <=0.3% | <=0.5% | <=1.0% | 0.5-0.8g/cm3 | 100-250um | 3-10um | View specificationsDiscuss this range |
| MF-DBP-B | <=0.3% | <=0.3% | <=0.5% | 0.5-0.8g/cm3 | 100-250um | 3-10um | View specificationsDiscuss this range |
| MF-DBP-C | <=0.5% | <=4.0% | <=1.0% | 0.4-0.7g/cm3 | 100-250um | 5-12um | View specificationsDiscuss this range |
Compare like with like.
The result is a catalogue-limit shortlist, not a measured batch result or an approval for your application. Blank inputs apply no filter. Missing upper limits never count as zero or automatically satisfy an entered limit.
Confirm the moisture and ignition-loss test conditions, reporting basis, shot sieve cut-off and separation method before comparing suppliers. Then obtain a current datasheet, batch information and samples, and validate mixing, forming and finished-product performance in your own formulation.
MEASUREMENT NOTES
Read the method behind the value.
Explore a topic when you need more detail. Test conditions, reporting basis and method scope matter when comparing two results.
Bulk and tapped densityUnderstand the volume a weighed fiber sample occupies before comparing handling and mixing requirements.
The principle
Bulk density includes the spaces between fibers. Mechanical tapping or vibration reduces that space; dividing sample mass by the final volume gives tapped bulk density. This is different from the true density of the solid fiber material.
Calculation reference
Tapped bulk density (g/mL) = net sample mass (g) / final tapped volume (mL)
Read the result
The second density board describes 250 ± 15 vibrations/min and a 3–5 minute cycle. These are separate photographed workshop procedures; their results should not be pooled without confirming the method.
How this helps your shortlist
Shortlist grades whose reported density range suits your volumetric feeding, mixer loading and forming process. Then check actual dispersion, filling and pressed-part consistency in your formulation.
Compare like with like
Match conditioning, cylinder size, filling technique, tap rate, movement, number of taps and endpoint. Confirm what “Apparent Density” means on the current grade datasheet.
Typical measurement workflow
- Take a representative portion and weigh its net mass using a clean, dry graduated cylinder.
- Fill consistently and record the initial volume if a loose-fill result is required. Do not describe a vibrated result as loose-fill density.
- Run the agreed tapping program and read the settled volume at the defined endpoint. The photographed board describes 25–100 mL cylinders, adjustable 100–300 taps/min and a 3 mm movement.
- The board describes three successive volume readings and averaging the calculated densities. Record whether repetitions use the same portion or independently filled portions.
Keep in mind
A higher density does not establish stronger fibers, a higher friction coefficient or better sealing. Compare like-for-like packing methods.
Background references
USP: bulk and tapped density principles (opens in a new tab)Fiber length and diameterCompare fiber geometry on a stated measurement basis, then balance reinforcement with dispersion.
The principle
Optical microscopy or a calibrated projection system measures individual dispersed fibers. The sample preparation, counting rule and averaging method affect the result; an average alone does not describe the full size distribution.
Calculation reference
Number-average length = sum of measured lengths / number of fibers measured
Read the result
The photographed method reports optical measurements; it is not evidence of a particular automated analyzer. Its result text uses mm, while the product catalogue uses µm.
How this helps your shortlist
Use the catalogue length and diameter ranges to identify candidates for your mixing and reinforcement needs. Check clumping, dispersion and fiber retention after processing before selecting a grade.
Compare like with like
Distinguish number averages, length-weighted averages and distribution percentiles. Ask whether measurements describe the supplied fibers or fibers recovered after processing.
Typical measurement workflow
- Collect portions from several positions so the test is not dominated by one clump. The board describes sampling from at least 20 positions and preparing three mixed portions.
- Disperse the fibers gently on slides using the specified mounting medium. Avoid preparation that unnecessarily breaks fibers.
- Calibrate the optical scale, then measure length and diameter using a documented counting rule. Agree the minimum fiber count per slide and per sample before comparing results.
- Report the number measured, units, average type and, when available, the distribution. Convert units explicitly: 1 mm = 1,000 µm.
Keep in mind
Longer is not automatically better. Do not divide unrelated range endpoints and describe the result as a measured average aspect ratio, or predict finished-brake performance from dimensions alone.
Moisture, drying loss and ignition lossSeparate low-temperature drying loss from the mass change measured during a higher-temperature ignition test.
The principle
Both procedures weigh a sample before and after heating. Drying loss can include substances other than water. Ignition loss records the net mass change under a specified furnace program; coatings, organic components and mineral reactions can all affect it.
Calculation reference
Loss (%) = (net starting mass − net mass after the specified treatment) / net starting mass × 100
Read the result
105 ± 2°C and 800 ± 20°C are conditions recorded in the photograph, not universal conditions for every grade or a claim of compliance with a cited standard.
How this helps your shortlist
Use agreed moisture and ignition-loss limits to narrow the catalogue, then investigate compatibility with your drying, hot pressing and curing process. A coated or composite fiber may intentionally have a different ignition loss.
Compare like with like
Confirm temperature, hold time, atmosphere, drying history, constant-mass criterion and reporting basis. A water-specific method may be needed if non-water volatiles interfere.
Typical measurement workflow
- Tare the sample container or crucible and weigh the net sample mass. The photographed procedures use approximately 2 g portions.
- For the photographed moisture procedure, dry at 105 ± 2°C to constant mass. Cool in a desiccator before weighing; record the endpoint criterion.
- For the photographed ignition procedure, heat at 800 ± 20°C for one hour, cool in a desiccator and weigh the residue.
- Calculate each loss against its stated starting mass. The board calls for duplicate measurements and their mean. Record whether ignition loss is reported as received or on a pre-dried basis.
Keep in mind
Ignition loss is not a maximum service temperature, fire rating or direct measurement of organic content. A lower value is not universally a better grade.
Non-fibrous shot contentMeasure a defined separated fraction of non-fibrous particles, with the sieve cut-off stated alongside the result.
The principle
Shot consists of non-fiberized mineral particles. The pictured wet method separates dispersed fibers and heavier particles by their behavior in flowing water, then dries, sieves and weighs the recovered fraction.
Calculation reference
Shot content (%) = dry retained shot mass / agreed reference sample mass × 100
Read the result
The calculation uses descriptive masses so the denominator is explicit. The pictured wet-separation procedure differs from the ASTM C1335 dry-sieve method; results require an agreed method and sieve cut-off.
How this helps your shortlist
Compare shot limits at the same particle-size cut-off and method, then assess the chosen fiber in your friction or sealing formulation. Particle content can be relevant to the formulation’s wear and surface-behavior requirements.
Compare like with like
A result for particles above 125 µm cannot be directly compared with one above another sieve size. Ask whether the denominator is the as-received mass or the mass after binder removal.
Typical measurement workflow
- Prepare a representative sample and define the reference mass. The photographed procedure starts with 10 g and includes binder removal at 600 ± 20°C for at least 30 minutes where applicable.
- Wet the prepared material with the specified surfactant solution and disperse it in the separation apparatus.
- The board describes an initial 60 mL/min water flow, followed by 120–180 mL/min for about 10 minutes. Collect the residue with the specified test sieve.
- The recorded drying step is 105–110°C for at least 20 minutes. The board then describes three 20 ± 1 mm ceramic balls and 15 minutes of vibratory sieving. Use the product-specified sieve opening and confirm treatment losses and the reference-mass basis.
Keep in mind
Shot is not simply a generic “impurity” value, and the lowest percentage does not by itself establish the best finished-product performance.
Coke-specific historical referenceVolatile matter: check the sample materialThe photographed volatile-matter board describes a coke procedure. It is not a routine mineral-fiber specification.

The principle
In a coke volatile-matter test, a covered crucible limits access of air while the sample is heated. The measured mass loss requires the appropriate moisture correction. This is a different measurement from ignition loss in air.
Calculation reference
Coke volatile matter (%) = mass loss under the specified covered-crucible test (%) − applicable moisture correction (%)
Read the result
The board explicitly names coke. ISO 562 also has a hard-coal/coke scope; citing it here explains the distinction and does not certify the photographed method.
How this helps your shortlist
If your formulation also contains carbonaceous ingredients, discuss their test basis separately. Do not use this board’s furnace temperature to assign a mineral-fiber heat-resistance rating.
Compare like with like
Confirm sample type, atmosphere, crucible, furnace recovery, hold time and moisture correction. Do not compare volatile matter and ignition loss as interchangeable percentages.
Typical measurement workflow
- Identify the sample as coke before applying this historical procedure. The board describes approximately 2 g in a preconditioned, covered crucible.
- The photographed program is 900 ± 10°C for seven minutes, followed by air cooling and cooling in a desiccator before weighing.
- Use the agreed moisture-corrected calculation. Raw mass loss alone is not automatically a volatile-matter result.
- For a mineral-fiber enquiry, first agree whether drying loss, ignition loss or a separately specified thermal-analysis method answers the actual processing question.
Keep in mind
No volatile-matter limits are added to the mineral-fiber catalogue from this photograph.
Background references
ISO 562: volatile matter in hard coal and coke (opens in a new tab)Material-family referenceRead the grade, not just the reference boardThe property board is an overview of two material families. A purchasing decision needs the selected grade’s current values and methods.

The principle
The translated headings cover appearance, predominant length and diameter, bulk density, ignition loss, moisture, shot, Mohs hardness and oxide composition. These are different properties; the photograph does not establish how each was measured.
Calculation reference
Useful comparison = same property + same units + same method + same reporting basis
Read the result
The original board has separate reinforcing-fiber and ceramic-fiber columns. Its broad ranges do not replace any product value in this website’s database.
How this helps your shortlist
Combine geometry, packing, moisture, ignition loss, shot and composition requirements. Use the catalogue selector on this page to narrow candidates, then confirm methods and validate samples in the complete formulation.
Compare like with like
For brake applications, agree the required friction, wear and noise testing of the finished component. For sealing, agree the relevant leakage, compression/recovery and media-compatibility checks.
Typical measurement workflow
- Choose the relevant mineral-fiber product family and open its grade-comparison table.
- Keep a typical value, a broad family range and a specified maximum distinct. Confirm the applicable measurement method and units.
- For composition entries such as SiO₂ or Al₂O₃, ask for the current analysis basis and method. The photo alone does not establish an instrument or analytical capability.
- Request the current datasheet and the agreed batch documentation for the shortlisted grade. A blank or “not specified” entry is not zero.
Keep in mind
A reference-board range is not a batch certificate, accreditation statement or guaranteed value for every grade.
Background references
ROCKWOOL: material consistency in friction formulations (opens in a new tab)Sources & scope of reference
These references explain measurement principles and their scope. They do not imply that a photographed procedure or a supplied product is certified to a listed standard.
- USP: bulk and tapped density principles (opens in a new tab)
- ISO 1888: fiber-diameter measurement (textile-glass scope) (opens in a new tab)
- METTLER TOLEDO: loss-on-drying measurement (opens in a new tab)
- ASTM D7348: ignition-loss principles and limitations (combustion-residue scope) (opens in a new tab)
- ASTM C1335: non-fibrous content (rock/slag insulation scope) (opens in a new tab)
- ISO 562: volatile matter in hard coal and coke (opens in a new tab)
- GB/T 5480-2017: mineral-wool test methods (opens in a new tab)
- ROCKWOOL: material consistency in friction formulations (opens in a new tab)
A photograph is not a batch report or an accreditation statement. Confirm the selected grade, current specifications and applicable methods before ordering.